In Total hip Arthroplasty the orientation, namely anteversion and inclination of the new acetabular component -cup- influences wear, range of movement (ROM), and the likelihood of dislocation after total hip replacement (THR). Evaluating objectively of the cup anteversion, and inclination in hip arthroplasty replacement surgery is of paramount importance. Radiographs are the most important diagnostic means in the follow-up for evaluation of a total hip arthroplasty. Measuring anteversion and inclination in everyday clinical setting is a cumbersome work for a medical doctor. Computation requires a calculator, which requires an additional effort during practice and slows down workflow.
The App is medical software aimed for orthopaedic surgeons, providing a tool that allow doctors to:
-Securely import medical images directly from the camera or stored photos.
-By marking certain anatomical landmark and points in a simple standard AP pelvic radiograph, values for cup inclination and anteversion are being calculated. The app is based on Widmer’s method which is the proven that is the most accurate compared to others.
-Pelvic tilt expressed by the angle APP is incorporated in measurements and can be adjusted manually according to surgeons preference.
-Radiographic Inclination (RI) and Radiographic Anteversion (RA) values are adjusted by taking into account pelvic tilt (APP angle).
- RI or RA values are printed in red or green, according to measured value in cases these are in certain range (Lewinnek at al), indicating if the positioning of the cup is optimal (green) or not (red).
-The data are printed over to screen so each case can easily assessed.
-For more accurate results the source of central ray of the x-ray should be at position at 1150mm away from x ray table .
-Save the planned images, for later review or consultation.
The app offers an easy way to quantify cup anteversion and inclination a quick and comfortable manner without the use of a goniometer or a ruler or to calculate elaborated formulas.
All information received from the software output must be clinically reviewed regarding its plausibility before patient treatment! The App is indicated for assisting healthcare professionals. Clinical judgment and experience are required to properly use the software.The software is not for primary image interpretation.
In a busy THA practice, the examiner to draw lines in X-rays, it is time consuming and cumbersome to calculate mathematics.This App is particular useful in clinical settings where you need a quick results without losing time. Please see tutorial videos at the developer’s web site www.orthopractis.com
Reference
1. Nomura T, Naito M, et al .An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographs. Bone Joint J. 2014 May;96-B(5):597-603.
2. Bachhal V, Jindal N, Saini G, Sament R, Kumar V, Chouhan D,
Dhillon M. A new method of measuring acetabular cup antev-
ersion on simulated radiographs. Int Orthop. 2012;36:1813–1818.
3. Widmer KH A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty. 2004 Apr;19(3):387-90.
5. Murray DW: The definition and measurement of acetabular orientation. J Bone Joint Surg Br 1993 75:228,
6. Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220
7. Schwarz TJ et al. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study. Rofo. 2017 Sep;189(9):864-873.
The App is medical software aimed for orthopaedic surgeons, providing a tool that allow doctors to:
-Securely import medical images directly from the camera or stored photos.
-By marking certain anatomical landmark and points in a simple standard AP pelvic radiograph, values for cup inclination and anteversion are being calculated. The app is based on Widmer’s method which is the proven that is the most accurate compared to others.
-Pelvic tilt expressed by the angle APP is incorporated in measurements and can be adjusted manually according to surgeons preference.
-Radiographic Inclination (RI) and Radiographic Anteversion (RA) values are adjusted by taking into account pelvic tilt (APP angle).
- RI or RA values are printed in red or green, according to measured value in cases these are in certain range (Lewinnek at al), indicating if the positioning of the cup is optimal (green) or not (red).
-The data are printed over to screen so each case can easily assessed.
-For more accurate results the source of central ray of the x-ray should be at position at 1150mm away from x ray table .
-Save the planned images, for later review or consultation.
The app offers an easy way to quantify cup anteversion and inclination a quick and comfortable manner without the use of a goniometer or a ruler or to calculate elaborated formulas.
All information received from the software output must be clinically reviewed regarding its plausibility before patient treatment! The App is indicated for assisting healthcare professionals. Clinical judgment and experience are required to properly use the software.The software is not for primary image interpretation.
In a busy THA practice, the examiner to draw lines in X-rays, it is time consuming and cumbersome to calculate mathematics.This App is particular useful in clinical settings where you need a quick results without losing time. Please see tutorial videos at the developer’s web site www.orthopractis.com
Reference
1. Nomura T, Naito M, et al .An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographs. Bone Joint J. 2014 May;96-B(5):597-603.
2. Bachhal V, Jindal N, Saini G, Sament R, Kumar V, Chouhan D,
Dhillon M. A new method of measuring acetabular cup antev-
ersion on simulated radiographs. Int Orthop. 2012;36:1813–1818.
3. Widmer KH A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty. 2004 Apr;19(3):387-90.
5. Murray DW: The definition and measurement of acetabular orientation. J Bone Joint Surg Br 1993 75:228,
6. Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220
7. Schwarz TJ et al. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study. Rofo. 2017 Sep;189(9):864-873.
このアプリはiPhone、iPadの両方に対応しています。
カテゴリー
メディカル
メディカル
リリース
2019/1/13
2019/1/13
更新
2020/2/22
2020/2/22
バージョン
3.5
3.5
言語
サイズ
1 MB
1 MB
条件
このバージョンの新機能
bugs fixed, calculation are now more precise, exclusively for radiologic anterversion and Inclination of cup.
bugs fixed, calculation are now more precise, exclusively for radiologic anterversion and Inclination of cup.
スクリーンショット - iPhone | iPad
スクリーンショット - iPhone | iPad
ORTHOPRACTIS.COM SINGLE MEMBER P.C. の他のアプリ » もっと見る
» 目的別iPhoneアプリ検索
- 辞書 » 日本語対応の辞書 » 英和辞典
- 学習 » 英単語 » 英会話 » クイズで楽しく
- スケジュール » 管理 » Googleカレンダー
たまひよ 妊娠・育児の赤ちゃんとママパパ応援アプリ まいにち..
Benesse Corporation無料無料 赤ちゃん名づけ 400万人の妊婦さんが子供の名付けで利..
Recstu Inc.無料第76回日本臨床外科学会総会 Mobile Planner
Japan Convention Services, Inc..無料陣痛時計
Simple Beep無料Yahoo!家庭の医学 - 症状や治療法を解説
Yahoo Japan Corp.無料たまひよ妊娠カウンター【たまプレ】
Benesse Corporation無料ナスカレ≪看護師のシフト表≫ナースのシフト共有カレンダーアプ..
株式会社クイック無料ストレススキャン カメラで手軽にストレスチェック!
Stress Scan Inc.無料赤ちゃん泣き止み音アプリ
BookLive Co., Ltd.無料きほんの離乳食 管理栄養士が監修したレシピが300種類以上!
Palsystem Consumers' Co-operat..無料
CatchApp新着アプリレビュー
様々な楽しみ方で運転士として成長していく鉄道運転士育成RPG「プラチナ・トレイン(プラトレ) 日本縦断てつどうの旅」
2016-05-17 00:00
日本語にはない英語発音のリスニングを楽しく学べる「発音どっち?英語リスニング 」
2014-12-20 12:00
指先の瞬発力が試されるカジュアルゲーム「早撃ちパニック」をリリース!
2014-12-08 15:21
新着アプリ動画